Full services directory How it worksFor prosAbout Get matched Call (866) 582-8523Decks more than 30 inches above grade require a guard at least 36 inches high with openings that will not pass a 4-inch sphere. Guard posts must be at least 4x4 nominal, spaced no more than 6 feet apart, and attached to framing members of at least 2x8. Stair guards are required where total stair rise is 30 inches or more, at a minimum height of 34 inches measured from the tread nosing.
Guards. The 36-inch minimum height and the 4-inch sphere rule get most of the attention, but the failure mode is almost always the post attachment, not the post. Under the prescriptive guide, guard posts must be at least 4x4 nominal with an adjusted bending design value of at least 1,100 psi, must not be notched, and where hold-down anchors are used they must have a minimum allowable tension load of 1,800 pounds for a 36-inch guard. A notched post is a known weak detail.
Stairs. Maximum riser height is 7 3/4 inches, minimum tread width 10 inches, and neither risers nor treads may vary from one another by more than 3/8 inch. Stairs must be at least 36 inches wide. Any stairway with four or more risers needs a handrail on at least one side, mounted 34 to 38 inches above the tread nosings, graspable, and returned at each end. If the total vertical stair height exceeds 12 feet, an intermediate landing is required. Openings in required stair guards must not pass a 4 3/8-inch sphere; triangular openings must not pass a 6-inch sphere.
The ledger. This is the connection between your deck and your house and it is the connection that kills people when it fails. Siding must be removed before the ledger goes on, approved corrosion-resistant flashing is required at the connection, and the ledger must be a minimum nominal 2x8. Older homes with thin band boards, metal-plate-connected wood trusses, or I-joist floor systems may not accept a standard ledger attachment at all — in those cases a freestanding deck or a full plan submission is required.
Lighting. Stairways must have a light source at the top landing that illuminates all stairs and landings, switched from inside the house, though motion or timed switches are acceptable. It is a code item and also the practical difference between a deck you use after dark and one you don't.
That is worth something only while you are still choosing. Tell us what is going on and we will match you with a few decks pros whose licence and insurance we have already checked — free, no obligation.