HVAC glossary

The HVAC terms that matter most on a quote are SEER2 and HSPF2 (cooling and heating efficiency ratings under DOE's revised test procedure, in effect since January 1, 2023), Manual J (the ACCA load calculation that sizes equipment to your house), AHRI match (the tested indoor-outdoor unit pairing that the efficiency rating applies to), and the refrigerant type, since R-410A and the newer low-GWP refrigerants are not interchangeable.

SEER2 / EER2 / HSPF2. Efficiency ratings under the M1 test procedure, which raises external static pressure from 0.1 to 0.5 inches of water — five times the prior test — to better reflect real installations. Higher is more efficient. Because the test is harder, SEER2 figures read lower than legacy SEER numbers for comparable equipment.

Manual J, S and D. ACCA's standard methods: Manual J calculates your home's heating and cooling loads, Manual S selects equipment to match, Manual D designs the duct system. ACCA notes these are referenced in building codes nationwide.

Tonnage, static pressure and AHRI match. Tonnage is cooling capacity (one ton equals 12,000 BTU/h). Static pressure is the resistance the blower fights against in your duct system — high static pressure means the ducts are choking the system. An AHRI match is the specific indoor and outdoor unit combination that was tested together, which is what the efficiency rating actually applies to.

How to choose

If a term on your quote isn't defined, ask
A contractor who can't explain a line item in plain English either doesn't know or doesn't want you to. Both are reasons to pause.
Efficiency ratings only apply to matched systems
Ask for the AHRI match reference number on the proposal.
Tonnage should come from Manual J, not the old nameplate
Copying the old system's size perpetuates a sizing error you may have lived with for two decades.
Ask which refrigerant the system uses
R-410A and newer low-GWP refrigerants are not interchangeable, per Lennox. It affects future service.
Static pressure is a diagnostic, not jargon
If a contractor measured it, they investigated your ducts. If nobody mentions it, nobody looked.
0 of 7 live

All hvac glossary

SEER2

HSPF2

AFUE

Tonnage

Manual J

Refrigerant

Load Calculation

FAQ

HVAC glossary — common questions

Still have a question? Talk to our team →

SEER2 uses DOE's revised M1 test procedure, effective January 1, 2023, which tests at five times the previous external static pressure. Same equipment, harder test, so SEER2 numbers read lower.
ACCA's standard method for calculating a home's heating and cooling loads, used to size equipment correctly. ACCA notes it is mandated by national building codes and most states.
A specific tested pairing of indoor and outdoor units. Published efficiency ratings apply to the matched pair, not to either component alone.
A lower-GWP refrigerant that manufacturers such as Lennox are using in new whole-home systems in place of R-410A. The two are not interchangeable.
Sources

Where these figures come from