Ice and Water Shield at a glance
| What it is | A self-adhering polymer-modified bitumen membrane (ASTM D1970) |
|---|---|
| Where it goes | Eaves, valleys, and around penetrations - under the roof covering |
| Code name | "Ice barrier" - IRC R905.1.2 |
| The 24-inch rule | From the eave edge to 24 in inside the exterior wall line |
| Steep roofs (8:12+) | Also applied 36 in measured along the slope from the eave |
| Typical cost | $4.00-$5.50/sq ft installed; rolls $100-$200 per 108-200 sq ft |
| Key property | Seals around nail shanks - no other underlayment does |
| Who installs it | The roofing crew, on bare deck before field underlayment |
| Commonly confused with | Standard underlayment, vapor barrier, the Grace brand name |
Quick answer: Ice and water shield is a self-adhering, polymer-modified bituminous membrane applied directly to the roof deck under the roof covering. Unlike any mechanically fastened underlayment, it seals around nail shanks driven through it. The building code calls it an ice barrier and requires it at eaves in cold regions, extending at least 24 inches inside the exterior wall line.
What it is and what makes it different
Ice and water shield is a peel-and-stick membrane. You pull off a release sheet, roll it onto the bare roof deck, and it bonds. It’s rubberized asphalt on a reinforced sheet, and it’s governed by ASTM D1970 - the standard specification for self-adhering polymer-modified bituminous sheet materials used as steep roofing underlayment for ice dam protection.
One property separates it from every other product in the underlayment family. ARMA names it directly: it seals around nail shanks. Every other underlayment is mechanically fastened, and every one of those fasteners is an open hole. Roofing nails then drive through the whole assembly. On most of the roof, that’s fine - water is moving fast and downhill and never sits. At the eave behind an ice dam, water isn’t moving at all. It sits, under pressure, sometimes for weeks.
That’s the problem this product exists to solve, and it’s why the code treats it as a distinct requirement rather than an upgrade.
ASTM D1970 tests thickness, maximum load, elongation, adhesion to plywood, thermal stability, flexibility, tear resistance, moisture vapor permeance, sealability and slip resistance - that last one because installers have to walk on it.
The name: what to call it and who makes it
“Ice and water shield” started as a trademark. Grace Ice & Water Shield was a GCP Applied Technologies product, and when Saint-Gobain acquired GCP in 2022 the line moved to CertainTeed and was renamed Grace Vycor Ice & Water Shield, as reported by Roofing Contractor.
The phrase is now used generically across the trade the way “Kleenex” is used for tissue, though that’s trade usage rather than any legal finding. Products you’ll see on quotes:
- Grace Vycor Ice & Water Shield (CertainTeed)
- Owens Corning WeatherLock
- GAF WeatherWatch and StormGuard
- CertainTeed WinterGuard
The code term is “ice barrier.” If you want to talk to your building department about what’s required, that’s the phrase that gets a straight answer. If you want to talk to your roofer, “ice and water” will do.
Worth noting: products differ in surfacing (granular vs smooth vs film), thickness, minimum application temperature and UV exposure window. Those are product-specific data sheet numbers, not category properties, so ask for the data sheet rather than assuming.
Where it goes in the roof assembly
Ice and water shield goes down first, on the bare deck, before field underlayment. The field underlayment then laps over its upper edge so water always runs onto the membrane rather than into the seam behind it.
The standard locations:
- Eaves - the code-driven application, sized by the 24-inch rule below
- Valleys - the highest-volume water path on any roof, typically a full-length 36-inch strip centered in the valley
- Around penetrations - skylights, chimneys, vent stacks
- Low-slope sections - pitches between 2:12 and 4:12, where full coverage of that section is often specified in place of double underlayment
- Rakes - common contractor practice, though we could not source a code requirement for it
Then drip edge, field underlayment, starter strip, and shingles on top.
The eave sequence is the fiddly part. ARMA describes an accepted approach: a 12-inch initial underlayment strip goes down, the drip edge fastens over it, then additional underlayment layers go above - which “sandwiches the drip edge between two plies of underlayment at the eave, thereby providing protection from melted snow/ice from below and/or above the eave.” It’s a small detail that’s easy to get backwards and impossible to inspect afterward.
The code: the 24-inch rule, read carefully
IRC R905.1.2 is the section. Its requirement:
“…not fewer than two layers of underlayment cemented together, or a self-adhering polymer-modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building. On roofs with slope equal to or greater than 8 units vertical in 12 units horizontal, the ice barrier shall also be applied not less than 36 inches (914 mm) measured along the roof slope from the eave edge of the building.”
Read the measurement again, because this is where installations go wrong: 24 inches inside the exterior wall line - not 24 inches up from the eave.
Work an example. A house with a 24-inch eave overhang and a 6-inch wall assembly needs coverage running the overhang (24 in) plus the wall thickness (6 in) plus 24 inches past it - 54 inches of horizontal coverage, before you convert to slope distance. A single 36-inch-wide roll doesn’t come close. Two rows minimum, often three.
That single misreading is the most common ice barrier deficiency in the field, and it’s invisible the moment the shingles go on.
One more wrinkle: the 2024 IRC removed the word “also” from the 8:12 sentence, which changes whether the 36-inch requirement is additional to the 24-inch rule or an alternative to it. Which edition your jurisdiction has adopted matters. Ask.
The requirement applies to asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, and wood shingles and shakes, per RoofingData.
Where it’s required, and where it isn’t
The code trigger is a local determination that there’s a history of ice forming along the eaves. That’s a jurisdictional call, not a national line on a map.
The practical pattern, per RoofingData:
- Climate Zones 5, 6 and 7 - mandatory
- Zone 4 - frequently adopted by local amendment, elevation and microclimate dependent
- Zones 1-3 - typically not enforced
Real examples of jurisdictions publishing their own version show how variable this gets: Rapid City, South Dakota has a municipal amendment to R905.1.2; Connecticut and Washington State publish their own R905.1.2 text; and Massachusetts issued a dedicated FAQ on ice barrier requirements because the question comes up so often.
Confirm with your building department. Do it before your contract is signed, because “we always do two rows” and “your code requires three” can be a four-figure difference discovered at inspection.
Even where it isn’t required, membrane at valleys and around penetrations is defensible on any roof in any climate - those are water-concentration points, and wind-driven rain doesn’t care about your climate zone.
What it costs
Installed, as part of a roofing project, ice and water membrane runs approximately $4.00 to $5.50 per square foot - meaningfully more than the $0.60-$2.70 range for standard underlayment. That’s $400-$550 per roofing square.
Material only:
| Product | Coverage | Price |
|---|---|---|
| Grace Ice & Water Shield | 108 sq ft roll | $150-$200 |
| Grace Ice & Water Shield | 36 in × 75 ft, 200 sq ft | - |
| Owens Corning WeatherLock Mat | 200 sq ft roll | ~$100 |
| Owens Corning WeatherLock G (granular) | 200 sq ft roll | ~$108 |
RoofCalc.org puts labor at $45-$75 per hour and a typical eave-and-valley job at $1,500-$2,500, with full coverage on a 2,000 sq ft roof at $3,850-$5,300.
The takeaway from those two numbers: the difference between the required eave-and-valley application and full-deck coverage is thousands of dollars. Which makes the next section worth reading before anyone sells you the upgrade.
Should it go on the whole roof? The honest answer
Some contractors install ice and water shield across the entire deck and market it as a premium roof. Building scientists disagree, and the disagreement is worth understanding because it’s your money and your roof structure.
The issue is vapor permeance. The membrane runs under about 0.5 perms - effectively vapor-closed. Standard underlayments are far more open; asphalt felt behaves as something close to a smart vapor retarder, its permeance rising when it’s wet.
A roof assembly needs to be able to dry in at least one direction. A vented attic with felt or a vapor-open synthetic can dry upward through the deck. Cover the whole deck in an impermeable membrane and that path closes. If the assembly can also not dry inward - an unvented cathedral ceiling, or one insulated with closed-cell spray foam - it can’t dry at all.
In the Green Building Advisor discussion, Robert Riversong describes full coverage as “a moisture trap,” and on a spray-foamed cathedral ceiling as “an insidious moisture trap that has a high probability of contributing to roof failure.” The governing principle stated in the thread is the one to carry away: “Things get wet - let them dry. When wetting rate exceeds drying rate, accumulation occurs.”
Where full coverage does make sense: low-slope sections between 2:12 and 4:12, where the code accepts it in place of double underlayment; and roofs where the specific assembly has been evaluated and has a reliable drying path.
Where it’s questionable: as a blanket upsell on a standard vented attic roof, and especially over an unvented or foamed assembly.
The related fix that actually reduces ice dams isn’t membrane at all - it’s air sealing the ceiling plane, adequate insulation, and balanced ridge vent and soffit ventilation that keeps the deck cold.
Common mistakes and misconceptions
“It prevents ice dams.” It does not. The dam still forms. The membrane keeps the water that backs up behind it from getting into the house.
Measuring 24 inches from the eave. The rule is 24 inches inside the exterior wall line. On a house with real overhangs that’s a difference of one row versus three.
Assuming one 36-inch roll satisfies the code. On most houses with meaningful overhangs, it doesn’t.
Full-deck coverage as a default upgrade. It’s a real building-science decision, not a free improvement, and it can hurt an assembly that can’t dry inward.
Installing below the minimum application temperature. The adhesive won’t bond, and the membrane can lift or fishmouth. Every product has a stated minimum - check it before a winter install.
Leaving it exposed past the UV window. Same problem as any underlayment: the product is partly spent before the shingles go on.
Skipping valleys. The code focus on eaves has left many roofs with membrane at the eave and plain felt in the valley, which is the wrong way round if you only get to do one.
Calling it by a brand name when talking to a building official. Ask about the “ice barrier” and the conversation goes faster.
How to check yours
While the roof is open during a reroof, this is the only hour it’s visible.
- Measure the coverage. Stand at the eave and measure how far up the membrane runs. Compare it to your overhang plus wall thickness plus 24 inches. If it doesn’t reach, say so before the shingles go on.
- Check the valleys. Full-length membrane, centered, running the whole valley - not a partial strip at the bottom.
- Check the penetrations. Membrane around chimneys, skylights and vent stacks before the flashing goes in.
- Photograph the roll label. Product name and ASTM D1970 compliance, for your records.
- Check the drip edge sequence at the eave against what your contractor described.
If your roof is already finished, your contract and material invoice are the record. Which is the argument for having ice barrier coverage described by dimension in the contract - “two courses at all eaves and full-length in all valleys” - rather than as a checkbox.
The bottom line
Ice and water shield is the only underlayment that seals around its own fasteners, which is why the code makes it the required product at eaves in cold regions and why it belongs in every valley regardless of climate. The measurement that governs it runs 24 inches inside the exterior wall line, not 24 inches from the eave - and getting that wrong is the most common failure in an otherwise good roof.
It’s also not a cure for ice dams, and covering the entire deck with it is a building-science decision rather than an automatic upgrade. Spend the money on the eaves, valleys and penetrations, then spend the rest on air sealing and ventilation.
Reroofing in a cold climate? Get a free estimate and have each contractor state their ice barrier coverage in dimensions, in writing.