Full services directory How it worksFor prosAbout Get matched Call (866) 582-8523Irrigation water sits in pipes above soil, fertiliser and whatever the dog left. A backflow preventer stops it being pulled back into drinking water. This is the one part of an irrigation system where the rules are not yours to choose.
A backflow preventer is a device on the connection between your drinking water supply and your irrigation system that only allows water to travel one way. It matters because irrigation pipework sits in soil, and if pressure in the main drops — a burst main, hydrant use, a pump failure — water can be drawn backwards out of the yard and into the potable supply. Which device you need, and how often it must be tested, is set by your water utility or local authority, not by your contractor.
Seeing something not on this list? Browse irrigation problems by symptom →
Ask the water utility what is required — first, not last
The device type, the installation position, whether a permit is needed, who is allowed to install it, who is allowed to test it, and how often it must be tested are all set by the water purveyor or local jurisdiction. These vary genuinely and substantially between neighbouring areas.
Watch for: A contractor who tells you the requirement without reference to your utility. Even good contractors carry assumptions from the last town they worked in. Get it from the utility in writing; it is usually a phone call.
Identify the hazard level of the connection
Cross-connection control is graded by how bad the consequences would be. Irrigation systems are generally treated as a higher hazard than an ordinary household fixture because of contact with soil, and systems that inject fertiliser or chemicals are treated as higher again.
Watch for: Any plan to add a fertiliser injector to a system without revisiting the backflow requirement. Chemical injection typically changes the hazard classification, and that changes the device.
Select the assembly type
The common families are pressure vacuum breakers, double check valve assemblies and reduced pressure zone assemblies, each with different protection levels and different installation constraints — several must sit a specified height above the highest outlet, which affects where it can physically go.
Watch for: A device installed below the height its type requires. It will pass a visual glance and fail its purpose, and a competent tester will fail it.
Check the device is an approved model
Approval programmes exist specifically for this. The USC Foundation for Cross-Connection Control and Hydraulic Research runs an approval programme for backflow prevention assemblies, and many utilities reference approved-assembly lists when deciding what they will accept.
Watch for: An unbranded or unlisted device. If it is not on the list your utility works from, it will not be accepted, and you will pay for the work twice.
Install with freeze protection and access in mind
Above-ground assemblies need to be reachable for annual testing and protected from freezing — insulated covers, or drain-down at winterization. Below-ground installations, where permitted, need a vault the tester can actually work in.
Watch for: A device installed tight against a wall or fence. The tester needs to attach gauges to test cocks on both sides; an assembly nobody can reach becomes a repeat charge every year.
Test, certify and file the paperwork
New assemblies are typically tested on installation and periodically thereafter. Testing is a hands-on procedure with a calibrated gauge, and the USC Foundation is one of the bodies that trains and certifies testers — it describes its tester courses as training attendees "in the intricacies of field-testing backflow prevention assemblies".
Watch for: A test with no certificate submitted to the utility. The test is not the deliverable; the filed report is. Ask who files it and get a copy for your own records.
Winterise the device correctly each year
In freezing climates, the assembly is the most freeze-vulnerable component in the entire system because it is above ground and full of water. It is drained or protected as part of shutdown.
Watch for: A blowout done without the backflow device being handled properly. A cracked assembly body is one of the more expensive irrigation repairs and it is entirely avoidable.
A device plus installation is a modest four-figure job at most, and often much less; periodic testing is a small annual charge. The variables are the assembly type your utility requires and whether a vault or freeze protection is needed. See the Cost Guide.
See the full backflow prevention installation cost guide — by material, size and region →
Everyone else ranking for this is paid when you say yes. Here's when you shouldn't.
Pressure vacuum breakers, double check assemblies and reduced pressure zone assemblies — protection level versus installation constraints.
What typically triggers a permit and an inspection on the irrigation connection.
Approved assemblies, enclosures and freeze protection.
Backflow prevention exists to keep contaminated water out of the public drinking supply — yours and your neighbours'. It is one of the few parts of home irrigation where the rules are set by a public authority and where the failure mode harms people other than you. In many jurisdictions installing or testing an assembly without the required certification is not permitted at all. Find out what applies at your address before deciding what you will do yourself.
What certification do you hold to install or test this, and can I see the number?
This is the one irrigation question where a certification number is a normal, expected answer. Testers are certified through programmes such as those run by the USC Foundation, and utilities usually keep a list of who they accept.
Which device does my water utility require at my address?
A contractor who works your area routinely will answer without hesitation. Hesitation here tells you they are working from a general assumption.
Who files the test report with the utility, and will I get a copy?
The filed report is what makes you compliant. A test without a filed report leaves you exactly where you started, minus the fee.
Is the assembly on my utility's approved list?
Approval programmes exist for these devices. Fitting a non-approved assembly means removing and re-fitting at your expense.
Where will it be mounted, and does that satisfy the required height and clearance?
Several assembly types must sit a specified height above the highest downstream outlet. Get this checked before it is plumbed in, not at the first test.
How is it protected over winter, and is that included in my winterization?
The backflow device is the most freeze-vulnerable part of the system. Make sure someone owns this task each autumn.
If it fails the test, do you repair or replace, and how is that priced?
There is an obvious incentive problem when the tester is also the seller. Agree in advance that a failure gets a diagnosis before it gets a quote.
Local pro matching for backflow prevention installation is rolling out by metro. Enter your ZIP and we'll match you with vetted pros in your area today.
Where the device gets fitted in the first place
Protecting the assembly through freezing weather
When nothing runs and the device is the suspect
Where cross-connection requirements are usually stricter