Full services directory How it worksFor prosAbout Get matched Call (866) 582-8523Ductless heating and cooling for rooms the ducts never reached. What it costs per zone, where the DIY kits genuinely work, and the point where you should be pricing central air instead.
A mini split is a ductless heat pump: an outdoor compressor connected by a slim refrigerant line set to one or more wall, ceiling or floor units inside. Each indoor head is its own zone with its own thermostat. A single-zone install is typically a half day to a day; multi-zone systems take longer because every head needs its own line run back to the outdoor unit.
Seeing something not on this list? Browse hvac problems by symptom →
Room-by-room load calculation
Each zone gets sized on its own, not on floor area. A south-facing sunroom with a lot of glass and a shaded interior bedroom of the same size need very different capacities.
Watch for: Sizing from a chart of square footage to BTU. Oversized mini split heads are worse than oversized ducted systems: an inverter compressor already modulates down, and a head that is too large for its room will sit at minimum output, cycle, and never dehumidify properly.
Single zone or multi zone
A single-zone system pairs one outdoor unit with one head. A multi-zone runs several heads from one outdoor unit. Multi-zone is tidier outside and shares one condenser; single zones are cheaper per unit, fail independently, and often modulate better.
Watch for: A multi-zone sold purely because it is one box outside. If one head is running and the others are off, some multi-zone systems run inefficiently at very low load. For two zones far apart in a house, two single-zone systems are frequently the better engineering answer.
Indoor head placement
Wall units usually go high on an interior or exterior wall with clear space around them and a straight path for the line set to leave the building. Ceiling cassettes and floor-mounted units exist for rooms where a high wall unit is impractical or unwelcome.
Watch for: A head placed where the line set is easiest to run rather than where the air needs to go. Blowing across a doorway, straight at a bed, or into a wardrobe alcove is a comfort complaint you will live with for fifteen years to save an afternoon of routing.
Outdoor unit siting
The condenser needs clearance for airflow, a level mounting pad or wall bracket, and somewhere that its noise and its winter defrost water are not a problem. In cold climates it is raised above expected snow depth on a stand.
Watch for: A condenser under a bedroom window or hard against a neighbour's boundary. It runs at night in summer. Also watch for units set at ground level in snow country — a heat pump that drifts over stops working when you need it most.
Line set routing and the wall penetration
A three-inch hole through the wall carries the refrigerant lines, condensate drain and control wiring. Outside they run in a line-hide cover to the condenser. Shorter and straighter runs perform better and cost less.
Watch for: Bare, untidy line sets taped to the exterior. It is not just cosmetic — unprotected insulation degrades in UV and the performance goes with it. Also make sure the condensate line falls continuously; a head that has to drain uphill needs a condensate pump, and that should be quoted, not improvised.
Electrical supply
Most systems need a dedicated circuit and a disconnect at the outdoor unit. Multi-zone systems and larger single zones frequently need 240V, which in an older house can mean panel work.
Watch for: The panel checked on install day rather than at the site visit. This is the most common cause of a mini split job stopping halfway through with the wall already drilled.
Evacuation, charge and commissioning
Lines are pressure-tested with nitrogen, evacuated to a deep vacuum, then the factory charge in the condenser is released. Longer runs need additional refrigerant added by weight to the manufacturer's specification.
Watch for: The extra charge for a long line run being skipped. It is a documented number in the installation manual, it is measured with scales, and omitting it quietly costs you capacity for the life of the system.
A single-zone mini split installed typically runs $3,000 to $6,000, with each additional zone adding a few thousand more. Line run length, whether a condensate pump or electrical work is needed, and ceiling cassettes versus wall heads are the main variables.
See the full mini split installation cost guide — by material, size and region →
Everyone else ranking for this is paid when you say yes. Here's when you shouldn't.
Two honest warnings on the DIY kits. Handling refrigerant without EPA Section 608 certification is regulated, which is why the DIY route uses sealed pre-charged line sets — go outside that and you are in territory you should not be in. And check the manufacturer's warranty terms before you buy: some void or reduce coverage on self-installed units.
How did you size each zone, and can I see the room-by-room numbers?
Per-room sizing is the whole point of a zoned system. A single figure for the house means it was not done.
Why single zone or multi zone for my layout?
There is a genuine engineering answer either way. A contractor who can explain the low-load behaviour of a multi-zone has thought about it; one who defaults to "one box outside is neater" has not.
Where exactly will each head go, and where will the line set run outside?
Agree this on the wall with tape before anyone drills. It is permanent and it is visible from your street.
How long is each line run, and are you adding the extra refrigerant charge for it?
A specific, documented number from the installation manual. A contractor who knows it off the top of their head is a good sign.
Does my electrical panel have capacity, and have you looked at it?
Should be settled at the site visit. Discovering it mid-install is how a one-day job becomes a two-week one.
What is this unit's rated output at my winter design temperature?
If you are heating with it, the 47°F rating tells you nothing about a January night. Ask for capacity at the temperature that actually matters where you live.
Who services this brand locally, and what is the parts lead time?
Some mini split brands are widely stocked and some are not. A three-week wait for a control board in February is a different product than the one you thought you bought.
Local pro matching for mini split installation is rolling out by metro. Enter your ZIP and we'll match you with vetted pros in your area today.